6
-136
* Factory
settings depend on Inverter capacity. (The values shown are for a 200 V Class Inverter for 0.4 kW.)
n
Changing
Frequency
Reference
and
Display
Units
Set
the Digital Operator frequency reference and display units using parameter o1-03. You can change the
units
for the following parameters using o1-03.
•
U1-01
(Frequency Reference)
•
U1-02
(Output Frequency)
•
U1-05
(Motor Speed)
•
U1-20
(Output Frequency after Soft Start)
•
d1-01
to d1-17 (Frequency references)
n
Switching
Monitors
when
the
Power
Supply
Is
ON
Using
parameter o1-02, select the monitor item (U1-
oo
[status monitor]) to be displayed on the Digital
Operator
when the power supply is turned ON. For monitors that can be displayed, refer to U1-
oo
in Chap-
ter
5 Parameters.
Setting
Precautions
If
selecting monitor parameters other than U1-01 (Frequency Reference), U1-02 (Output Frequency), and U1-
03
(Output Current), first select the monitor items to be displayed in o1-01, and then set o1-02 to 4.
n
Disabling
the
STOP
Key
If
b1-02 (Operation Method Selection) is set to 1, 2, or 3, the stop command from the STOP Key on the Digital
Operator
is an emergency stop command.
Set
o2-02 to 0 to disable emergency stop commands from the STOP Key on the Digital Operator.
n
Disabling
the
LOCAL/REMOTE
Key
Set
o2-01 to 0 to disable the LOCAL/REMOTE Key on the Digital Operator. You cannot switch Inverter ref-
erence
inputs set using reference inputs from the Digital Operator, b1-01 (Reference Selection), or b1-02
(Operation
Method Selection).
o2-05
Frequency
reference set-
ting
method selection
Sets
the operation when the Digital Operator is
disconnected.
0:
Enter key needed
1:
Enter key not needed
Inverter
output is cut off, and fault contact is
operated.)
0
or 1
0
No
A
A
A
Operator
M.O.P.
o2-07
Cumulative
operation time
setting
Sets
the cumulative operation time in hour units.
Operation
time is calculated from the set values.
0
to
65535
0
No
A
A
A
Elapsed
Time Set
o2-10
Fan
operation time setting
Set
the initial value of the fan operation time using
time
units.
The
operation time accumulates from the set
value.
0
to
65535
0
No
A
A
A
Fan
ON Time Set
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display