Monitor Parameters
6-
75
n
Adjusting
the
Pulse
Monitor
Items
Adjust
the pulse frequency output from pulse monitor terminal MP-SC. Set the pulse frequency output when
100%
frequency is output to H6-07.
Set
H6-06 to 2, and H6-07 to 0, to output the frequency synchronous with the Inverter's U-phase output.
n
Application
Precautions
When
using a pulse monitor parameter, connect a peripheral device according to the following load condi-
tions.
If the load conditions are different, there is a risk of characteristic insufficiency or damage to other
devices.
Using
a Sourcing Output
Output
Voltage
(Iso-
lated)
VRL
(V)
Load
Impedance
(k
Ω
)
+5
V min.
1.5
k
Ω
min.
+8
V min.
3.5
k
Ω
min.
+10
V min.
10
k
Ω
min.
Load impedance
MP
AC
VRL
Using
a Sinking Input
External
Power
Supply
(V)
12
VDC
±
10%,
15
VDC
±
10%
Sink
Current (mA)
16
mA Max
Load impedance
Sinking current
External power supply
MP
AC