Parameter Tables
5-
35
n
Motor
2
V/f
Pattern:
E3
Parameters
for motor 2 V/f characteristics are shown in the following table.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register
Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
E3-01
Motor
2
control
method
selection
0: V/f
control
1: V/f
control with PG
2:
Open-loop vector control
0
to 2
0
No
A
A
A
319H
-
Control
Method
E3-02
Motor
2
max.
out-
put
fre-
quency
(FMAX)
To
set V/f characteristics in a
straight
line, set the same values
for
E3-05 and E3-07.
In
this case, the setting for E3-06
will
be disregarded.
Always
ensure that the four fre-
quencies
are set in the following
manner:
E3-02
(FMAX)
≥
E3-04 (FA) >
E3-05
(FB) > E3-07 (FMIN)
40.0
to
400.0
*3
60.0
Hz
(50.0
Hz)
*4
No
A
A
A
31AH
-
Max
Fre-
quency
E3-03
Motor
2
max.
volt-
age
(VMAX)
0.0
to
255.0
*1
200.0
V
*2
No
A
A
A
31BH
-
Max
Volt-
age
E3-04
Motor
2
max.
volt-
age
fre-
quency
(FA)
0.0
to
400.0
60.0
Hz
(50.0
Hz)
*4
No
A
A
A
31CH
-
Base
Fre-
quency
E3-05
Motor
2
mid.
out-
put
fre-
quency
1
(FB)
0.0
to
400.0
3.0
Hz
*2
No
A
A
A
31DH
-
Mid
Fre-
quency
E3-06
Motor
2
mid.
out-
put
fre-
quency
voltage
1
(VC)
0.0
to
255.0
*1
15.0
V
*1
No
A
A
A
31EH
-
Mid
Volt-
age
E3-07
Motor
2
min.
out-
put
fre-
quency
(FMIN)
0.0
to
400.0
1.5
Hz
*2
No
A
A
A
31FH
-
Min
Fre-
quency
Output voltage (V)
Frequency (Hz)