Acceleration and Deceleration Characteristics
6-
19
Acceleration
and
Deceleration
Characteristics
This
section explains the acceleration and deceleration characteristics of the Inverter.
K
K
K
K
Setting
Acceleration
and
Deceleration
Times
Acceleration
time indicates the time taken for the output frequency to climb from 0% to 100%. Deceleration
time
indicates the time taken for the output frequency to reduce to 0%. The factory setting of the acceleration
time
is C1-01, and the factory setting of the deceleration time is C1-02.
n
Related
Parameters
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
C1-01
Acceleration
time 1
Set
the acceleration time to accelerate from 0 to
the
maximum output frequency, in 1-second units.
0.0
to
6000.0
*
10.0
s
Yes
Q
Q
Q
Accel
Time 1
C1-02
Deceleration
time 1
Set
the deceleration time in seconds for the output
frequency
to fall from 100% to 0%.
Yes
Q
Q
Q
Decel
Time 1
C1-03
Acceleration
time 2
Acceleration
time when multi-function input
"Acceleration/deceleration
time selection 1" is
ON.
Yes
A
A
A
Accel
Time 2
C1-04
Deceleration
time 2
Deceleration
time when multi-function input
"Acceleration/deceleration
time selection 1" is
ON.
Yes
A
A
A
Decel
Time 2
C1-05
Acceleration
time 3
Acceleration
time when multi-function input
"Acceleration/deceleration
time selection 2" is
ON.
No
A
A
A
Accel
Time 3
C1-06
Deceleration
time 3
Deceleration
time when multi-function input
"Acceleration/deceleration
time selection 2" is
ON.
No
A
A
A
Decel
Time 3
C1-07
Acceleration
time 4
Acceleration
time when multi-function input
"Acceleration/deceleration
time selection 1" and
"Acceleration/deceleration
time selection 2" are
ON.
No
A
A
A
Accel
Time 4
C1-08
Deceleration
time 4
Deceleration
time when multi-function input
"Acceleration/deceleration
time selection 1" and
"Acceleration/deceleration
time 2" are ON.
No
A
A
A
Decel
Time 4
C1-10
Acceleration/deceleration
time
setting unit
0:
0.01 s
1:
0.1 s
0
or 1
1
No
A
A
A
Acc/Dec
Units
C1-11
Acceleration/deceleration
time
switching frequency
Set
the frequency at which acceleration/decelera-
tion
time switches automatically.
Less
than set frequency: Acceleration/deceleration
time
4
Set
frequency or above: Acceleration/deceleration
time
1
Multi-function
inputs "Acceleration/deceleration
time
selection 1" and "Acceleration/deceleration
time
selection 2" are given priority.
0.0
to
400.0
0.0
Hz
No
A
A
A
Acc/Dec
SW Freq
Summary of Contents for SYSDRIVE 3G3RV
Page 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Page 36: ...1 22...
Page 106: ...3 14...
Page 126: ...4 20...
Page 216: ...5 90...
Page 388: ...7 26...