Speed Limit (Frequency Reference Limit Function)
6-
33
n
Adjusting
Frequency
Lower
Limit
Using
an
Analog
Input
If
you set parameter H3-09 (Multi-function Analog Input Terminal A2 Function Selection) to 9 (output fre-
quency
lower level), you can adjust the frequency lower level using the terminal A2 input level.
Fig 6.33 Analog Output Characteristics of Output Frequency Lower Level
INFO
If parameter d2-02 and terminal A2 output frequency lower level have been set at the same time, the larger
set value will become the frequency lower limit.
Output frequency lower level
0 V
(4 mA)
Multi-function analog input
terminal A2 input level
10 V
(20 mA)
Max. output frequency
E1-04