Communications Functions
6-
105
Response
Determine
whether or not to write the reception data in the response.
Always
set this parameter to Yes for communications with the 3G3RV.
Next
Determine
which step is to be processed next or finish the operation after the step finishes normally.
In
this example, step 00 is set to Next and step 01 is set to END because the sequence completes be executing
steps
00 and 01.
Error
If
the step has an error, determine which step is to be processed next or finish the operation.
In
this example, the parameter will be set to Abort to interrupt the sequence if an error occurs.
n
Send
Message
Detail
Settings
1. Click
on Send Message List with the left button of the mouse, and then click on a blank space with the
right
button of the mouse.
2. Select
Create Send Message. The following table will appear. Set the send message in the table.
Message
name
The
label (name) of the sequence. Input an appropriate, easy-to-distinguish name.
Set
the label in the send message box in the table shown under Creating a Step.
Header
<h>
and
Terminator
<t>
Set
the header and terminator.
No
header or terminator is used for communications with the 3G3RV. Therefore, set both to None.
Check
code
<c>
Set
the check code.
The
CRC-16 check code is used for communications with the 3G3RV. Select the CRC-16 check code and set
the
default value to 65535.
Select
Reverse for the conversion method. Then select BIN for data type.
Header <h>
Check code <c>
CRC-16 65535
2Byte BIN
Length <l>
0
1Byte BIN
Address <a>
R 3N
2
1
Data
Message name
Input send
Status
CRC-16 65535
2Byte BIN
R 3N
2
1
a
10
00
01
00
02
l
R 3N
3
4
c
a
03
00
2C
00
01
c
Terminator <t>
Summary of Contents for SYSDRIVE 3G3RV
Page 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Page 36: ...1 22...
Page 106: ...3 14...
Page 126: ...4 20...
Page 216: ...5 90...
Page 388: ...7 26...