8. Maintenance Functions
8.1 Data Input/Output Function
III
-50
8. Maintenance Functions
The machining programs, parameters and tool data, etc., are saved in the memory. However, these
contents could be lost due to the battery life, etc. To avoid total loss, save the machining programs,
tool data and parameters in an input/output device.
8.1 Data Input/Output Function
The data can be collectively input/output or collated in the data input/output screen. This function can
be used to protect data and investigate failure causes at the customer premises. It can handle three
types of data shown below. Hex data is converted and output in the ISO/EIA format. Individual data
items can also be input/output or collated separately. This function is valid only while the user PLC is
halted.
1. Table data: The data area is reserved in advance.
Parameter
(system, common, axis, machine error)
PLC data (PLC timer, PLC counter, PLC constants, bit selection, ATC data, axis control)
Work offset data
Backup data (PLC latch relay, PLC switch, program No.)
2. File data: The file format is required before data input.
Tool offset data
Common
variables
Tool life control data
3. PLC program data: PLC program area data
Ladder
(ROM: Ladder, message)
Screen
Setting
Display
RS-232C device
Input
Output
PLC
ladder
Tool offset
Common
variables
Tool life
PLC axis
parameter
PLC data
PLC timer,
PLC
counter
Backup data
PLC switch,
latch relay,
program No.
R register
PLC constant,
bit selection,
ATC data, user
backup
Parameter
table
System,
common axis,
machine error,
work, offset
ク
Fixed cycle
program
Machining
program
1
2
3
Summary of Contents for EZMotion-NC E60 Series
Page 1: ......
Page 15: ...I OPERATION SECTION ...
Page 361: ...II MACHINE OPERATION MANUAL ...
Page 399: ...III SETUP ...
Page 472: ...IV APPENDIXES ...
Page 510: ......