8. Maintenance Functions
8.1 Data Input/Output Function
III
-58
8.1.3 Data Input and Compare
(1) Explanation of function
When the PLC is stopped, the data output from the input screen can be input and compared.
The target data is the same as for data output.
This function is valid only when the user PLC is stopped.
(Note
1)
If data that exceeds the actual memory size is input or compared, the data of the memory size
will be read in and then the message "E10 MEMORY OVER" will display. The operation will
stop.
(Note
2)
The data protection key setting will basically be ignored.
(Note
3)
To stop the PLC, enter the emergency stop state, and then set rotary switch NCSYS to "1".