5. Stored Stroke Limit
5.1 Stored stroke limit I
III
-28
5.1 Stored stroke limit I
This is a stroke limit function used by the machine maker. The boundary is set with the parameters (axis
specification parameters "#2013 OT–" and "#2014 OT+"). The outside of the set boundary is the
prohibited range.
When used with the stored stroke limit II function, the narrow range designated by the two types
becomes the movement valid range.
Basic machine coordinate system
Point 1
P
rohi
bi
te
d range
Machine movement valid range
– setting value
P
rohi
bi
te
d range
Point 2
+ setting
value
The following values are set
with the coordinate values in
the basic machine coordinate
system.
Point 1: #2014 OT+
Point 2: #2013 OT–