2. Monitor
2.1 POSITION
I
-23
(3) Action to be taken when an erroneous numeric is set and the correct one is desired to be
set
There are two methods:
Method (1) While pressing the
DELETE
INS
key, delete the set digits one by one. Then, retry to enter
the correct digits.
Method (2) Retry the entry, beginning with pressing the address key corresponding to the
command.
Press
DELETE
INS
DELETE
INS
DELETE
INS
to delete the
erroneously set numeric.
(Example)
In this condition, the numeric is
desired to be replaced by S1500.
S 1200
Method (1)
S 1
Enter
5
0
0
.
S 1500
Press address key
S
to return to
the initial status.
Method (2)
S
Enter
1
5
0
0
.
S 1500
(4) Setting/output range of manual numeric command
The setting and output range for the manual numeric command are indicated.
BCD
Signed binary
M 0~9999
S ±99999
T 0~9999