8. Maintenance Functions
8.1 Data Input/Output Function
III
-62
(5) Example of data input operation
Confirm that the user PLC is
stopped.
Connect the input device.
Call out the data input screen, and
enter the compare mode.
# (10) data ( 2)
INPUT
1) The compare mode is canceled
when the screen is changed,
and the input mode will be
validated. Thus, the mode must
be set again.
Set 9 9 in # setting area.
# (99) DATA ( )
<INPUT DATA>
N2L10001LF0000L0L0;
<COMP. DATA>
N2L10001LF0000L0L0;
COMPARE
EXECUTION
# (9 9 ) DATA ( 101 )
<INPUT DATA>
%
<COMP. DATA>
%
COMPARE
COMPLETE
# ( ) DATA ( )
1) The compare will start, and the
data being compared and
"COMPARE EXECUTION"
message will display.
The No. of the data will display
in the data setting area.
2) When the data is compared
normally to the end and the
end code % (EOR) is read in,
the message "COMPARE
COM-PLETE" will display.
3) If a compare error occurs, the
message "E35 COMPARE
ERROR" will display, and the
operation will be stopped.
Press
INPUT
key.
<INPUT DATA>
<COMP. DATA>
# (9 9 ) DATA ( )