Appendix 6. Operation Messages on Setting and Display Unit
IV
-27
Error No.
Error message
Details
E82 ALREADY
RESEARCH
×
• After completing the type 1 or type 2 search for program restart,
the unmodal type, type 1 or type 2 search was attempted again.
If program restart is continued (if the axis is return to the restart
position with automatic or manual operations), the program will
restart from the block searched for first.
To search again, cancel the previous search by resetting, and
then search again.
E84 CAN’T
IN/OUT
×
• An attempt was made to input a parameter in the setup
parameter locked state. Refer to the manual issued by the
machine manufacturer.
• When writing data to the IC card, the file name is illegal.
(Exceeding 8 characters of file name + 3 characters of
extension.)
• Input of maintenance data from the host or IC card was
attempted.
E86
INPUT DATA ERR
×
• When inputting the tool offset data‚ the data format was not
correct‚ so that block could not be input.
• If the INPUT key is pressed again in the input screen‚ the input
will continue from the next block.
• When data is read from parameter tape, its format is incorrect.
• The format of file written to the NC memory is illegal.
E87
NOT EDIT PROG.
×
• Playback edit was executed for a fixed cycle subprogram.
Playback edit of a fixed cycle subprogram is not possible.
E88 CAN’T
ADD
BLOCK
×
• Playback edit cannot be executed unless the block being edited
with playback is displayed to the end (EOB) on the left side of the
machining program display area. Press the cursor key
↓
‚ and
display the whole block to the end. Then‚ input the data.
E91 MODE
ERROR
(PBK)
×
• G90 was set when "PB_G90" was OFF.
• G91 was set when "PB_G90" was ON.
E98 CAN’T
RESEARCH
×
• When restarting the program, the type 3 restart search was
attempted with a program containing no T command. Check the
program.
• When restarting the program, the T command corresponding to
the type 3 restart search was not found in the program. Check the
program.
• When carrying out program restart, restart search 2 was
executed during MDI mode.
• When carrying our program restart, type 3 restart search was
attempted while the machine was at the negative (–) side of the
restart limit parameters. Manually move the machine to the
positive (+) side of the restart limit parameters, and search again.