8. Maintenance Functions
8.2 Data Sampling
III
-69
Setting range (index No.)
Servo axis
1st axis
2nd axis ...
6th axis
Feedback position
000100
000200
...
000600
Command position
000101
000201
...
000601
Spindle
1st axis
2nd axis
Feedback position
010000
020000
Command position
010001
020001
(Note)
The number of axes that can be used depends on the specifications.
High-order 4 digits: Axis index
High-order 2 digits : Spindle index (01 to 02)
Low-order 2 digits : Servo axis index (01 to 06)
Low-order 2 digits: Sampling target index
00: Feedback position
01: Command position
* Examples of setting for each purpose are shown below.
•
Synchronized tapping
setting
: 3rd servo axis FB (000300)
- 1st spindle FB (010000)
•
High-accuracy setting
(roundness)
: 1st servo axis FB(000100)
- 2nd servo axis FB(000200)
•
Spindle synchronization
setting
: 1st spindle FB (010000)
- 2nd spindle FB (020000)
(b) Actual address method
If the actual address is known beforehand, it can be set by directly inputting it.
However, if an illegal address (highest-order bit 0) is input, a setting error will occur.
If an address that does not exist is set, the system could fail.
(Note)
Even if the data does not match near the 4th byte, "E02 DATA OVER" will occur.
(c) Head address automatic setting method
When the symbol is set in the setting area, the head address of that symbol will be searched
for, and will be automatically set as the sampling address.
Normally, the data to be actually sampled is the actual address obtained by adding the data
offset (relative address from address determined with symbol) to the address determined with
this method.
When setting a symbol containing "_", substitute "=".
(Note 1)
The symbols are limited to NC internal table symbols having within 16 digits.
(Note 2)
The symbols are searched for as all lowercase symbols.
(Note 3)
If there is no symbol, "E01 SETTING ERROR" will occur, and if the symbol is not
found within the 4 bytes, "E02 DATA OVER" will occur.