7. Diagnosis
7.4 PLC Interface Diagnosis
I
-271
7.4.3 PLC Interface Signal Forcible Definition (Single-shot Type)
This function is used to forcibly define signals to check the PLC functions.
This function is available for the following device numbers: X, Y, U, W, S, M, G, F, L, E, T, Q, C, B, D,
and R.
(1)
Mode
setting
Set the device number to be forcibly set in DEVICE ( ), definition data in DATA ( ), and 1 in
MODE ( ), then press the
INPUT
key. The setup data is processed and forcibly defined at the top
of one cycle of user PLC.
Press the
INPUT
key.
Set M23 in DEVICE ( ),
1 in DATA ( ), and
1 in MODE ( ).
ALARM SERVO SPINDLE
PLC-I/F
MENU
[PLC-I/F]
ALARM/DIAGN 4
<SET
DATA>
76543210
HEX
76543210
HEX
M0000 oooooooo
00
D0005 oooooooo
00
M0008 ooooo1o1
05
o11oo1oo
64
M0016 oooooooo
00
D0006 1oooooo1
81
M0024 o1o1oooo
50
ooooo1oo
04
DEVICE DATA
MODE DEVICE DATA MODE
( M23 ) ( 1 ) ( 1)
( ) ( ) ( )
[PLC-I/F]
ALARM/DIAGN 4
<SET
DATA>
76543210
HEX
76543210
HEX
M0016 oooooooo
80
D0005 oooooooo
00
M0024 ooooo1o1
50
o11oo1oo
64
M0032 oooooooo
A3
D0006 1oooooo1
81
M0040 o1o1oooo
82
ooooo1oo
04
M0016 is displayed at the beginning and bit 7 changes
to 1. (If device M23 OUT instruction comes within one
cycle of user PLC, the sequence processing results
will follow.)
(Example 2)
Data is not displayed in the SET DATA field at the screen top.
CAUTION
When forcibly setting (forcibly outputting) data on the I/F diagnosis screen during machine
operation, pay careful attention to the sequence operation.
(Note)
An input signal (X or U) to the PLC is updated at the beginning of each cycle of the PLC.
Therefore, the signal, once forcibly defined in single-shot type mode, is restored after one
cycle.