7. Diagnosis
7.4 PLC Interface Diagnosis
I
-272
7.4.4 PLC Interface Signal Forcible Definition (Modal Type)
This is PLC interface signal forcible definition of modal type. Once it is set, it is held until canceled.
The device signals that can be set by using this function are X, Y, U, W, S, M, G, F, L, E, T, Q, C, B, D
and R.
(1)
Mode
setting
Set the device number to be forcibly defined in DEVICE ( ), definition data in DATA ( ), and 2 in
MODE ( ), then press the
INPUT
key. The data is processed and forcibly defined.
[PLC-I/F]
ALARM/DIAGN 4
<SET
DATA>
X0008=0001
76543210
HEX
76543210
HEX
X0008 ooooo1o1
05
D0005 oooooooo
X0010 oooooooo
00
o11oo1oo
X0018 o1o1oooo
50
D0006 1oooooo1
X0020 1o1ooo11
A3
ooooo1oo
[PLC-I/F]
ALARM/DIAGN 4
<SET
DATA>
76543210
HEX
76543210
HEX
X0000 oooooooo
00
D0005 oooooooo
00
X0008 ooooo1o1
04
o11oo1oo
64
X0010 oooooooo
00
D0006 1oooooo1
81
X0018 o1o1oooo
50
ooooo1oo
04
DEVICE DATA
MODE DEVICE DATA MODE
( X8 ) ( 1 ) ( 2)
( ) ( ) ( )
Press the
INPUT
key.
Set X8 in DEVICE ( ),
1 in DATA ( ), and
1 in MODE ( ).
ALARM SERVO SPINDLE
PLC-I/F
MENU
X0008 is displayed at the beginning and bit 0 changes to "1".
(Example 3)
A maximum of four sets of forcibly
defined device numbers and
numeric data are displayed.
A maximum of four sets can be forcibly defined in mode 2. If four sets have been defined and
additional setting is made, forward feed is made and the subsequent four sets become effective.