11. Visual Analyzer (Waveform display)
I
-343
# Parameter
Description
Setting range
(units)
3
data
Specify data to be sampled.
(Servo axis) (Spindle)
1 to 7
1: Current FB (%)
2: Current command (%)
3: Position deviation (µm)
4: Position command (µm)
5: Speed FB (r/min)
1: Motor load (%)
2: Motor rotation speed
(speed command value)
(r/min)
3: Position deviation (µm)
4: Position command (µm)
5: Srpm (speed FB) (r/min)
6: Synchronous error
width (µm)
7: Synchronous error
angle (0.001
°
)
The position command and deviation and synchronous
tap error width are displayed with an mm unit even when
inch specifications are set.
4 range
Specify the size of the vertical axis.
That is, specify the size of six gradations equivalent to
the half of the screen.
(Example 1) In case of current FB
When #4= 400, the upper half of the screen is 400%
and the lower half of the screen is –400%.
(Example 2) In case of position deviation
When #4= 18000, 18,000
µ
m (18mm)
(Example 3) In case of synchronous error width (
µ
m)
When #4 = 6000, the scale increment for the vertical
axis will be 1mm (1000
µ
m).
(Example 4) In case of synchronous error angle (0.001
°
)
When #4 = 6000, the scale increment for the vertical
axis will be 1
°
.
1 to 999999
5
level
Specify the position of level 0 on the vertical axis.
That is, specify the position of the current and speed 0
level on the scale.
In the case of a position command or position deviation,
the display start position is displayed at the specified
gradation.
–6 to 6
6
CH2 ax
Specify the name of the axis to be displayed for CH2.
No waveform data is displayed if ( ) is left blank.
Input "/" to erase the displayed waveform.
Refer to the
setting range for
"#2 CH1 axis".
7
data
Refer to "#3 data". (#7 is used for CH2.)
1 to 7
8
range
Refer to "#4 range". (#8 is used for CH2.)
1 to 999999
9
level
Refer to "#5 level". (#9 is used for CH2.)
–6 to 6
10
type
Specify the condition to stop waveform display in
continuous mode.
0: Continuous menu OFF
2: #11 signal ON
3: #11 signal OFF
Display will stop when the continuous menu is turned
OFF regardless of the stopping conditions.
0, 2, 3
11
signal
Specify the stop signal name in hexadecimal number
preceded by X or Y.
X00 to XFF
Y00 to YFF
(Note 1)
Only the servo axis name set in "#1022 axname2" can be set in #2 and #6.
(Note 2)
Only bus connected spindle (#3024 sout=1) can be set in #2 and #6.