8. Maintenance Functions
8.1 Data Input/Output Function
III
-63
8.1.4 Parameter Backup
(1) Explanation
of
function
The parameter backup function is used to back up and restore the NC parameters, etc. (including
options).
(2) Backup
targets
The backed up data is ALL1 (table data 1), ALL2 (file data) and ALL3 (PLC Programs) in the "99
maintenance data" set with data input/output, and the machining programs. Refer to section "8.1.1
Data Format" for details.
(Note 1)
Only ALL1 and ALL3 are backed up with E60 system software version A.
(3) Hardware
configuration
The backup cassette (HR410 or HR450) is used to backup and restore the data.
The backup cassette is mounted on CBUS in the NC control unit.
NC control unit (back side)
CBUS
(Note 2)
The backup cassette HR450 is not compatible with the E60 system software version A.
(4) Operation
methods
The data is backed up and restored using the BACKUP screen. Refer to section "4.5 BACKUP
Screen" in "