9. Graphics
9.6 SCALE
I
-336
(4) Retaining scale and display position
The display range (scale and display position) can be retained even after the NC power is turned
OFF and ON, depending on the parameter setting.
Regardless of the parameter setting, while the NC power is ON, the set display range will be
retained even if the screen is changed.
While the display range is being set, if the setting of display range is canceled by pressing the
SCALE
menu key again, the default display range will be retained.
This parameter will be valid immediately after the setting.
Base specification
parameter
#1231 set03/bit3
Contents
0
When the power is turned OFF and ON, the set display range (scale
and display position) is retained.
1
When the power is turned OFF and ON, the default display range is
set.