4. Parameters (User)
4.1 Workpiece Coordinate
I
-143
Return by the return amount of
measurement parameter (#8705).
6)
Return
amount
Complete the measurement. Next
measurement can be performed.
7)
The speed for returning of 3), 6) are 40 times higher than the feed rate of measurement
parameter (#8706). However, when the speed for returning is higher than rapid traverse feed
rate (override 100%), the rapid traverse feed rate of parameter (override 100%) will be applied.
(6)
Restrictions
a) Measurement points A, B and C are unhighlighted and reset to 0 (not set) when the
measurement switch is turned ON/OFF, setting to the workpiece coordinate offset ends, and
when the reset key is pressed.
b) Only 1st system axes can be used as measurement target axes. The measurement target axis
corresponds to base-axis (#1026 base_I, #1027 base_J, #1028 base_K).
c) An error will not occur during the measurement, even if there is the axis movement other than
that of the base-axis.
d) The skip machine position and measurement points A, B and C are held even when the screen
changes during measurement.
e) An axis other than the measurement axis cannot be moved during the automatic re-contact
movement.
f) When the return amount of measurement parameter or feed rate is 0, first contact point is
measurement point, so automatic re-contact movement is not performed.
g) Perform the measurement during the movement by moving only one axis.
h) The settings of the workpiece coordinate offset of surface, hole center and width center
measurement during measurement are set in absolute value mode.
i) If rotary axis is set to measurement axis, the hole center / width center cannot be calculated
properly by the angle of the rotation axis.