6. Data In/Out
6.2 DATA OUTPUT
I
-234
(3)
Data
format
The data format is as follows:
Address
Definition
Details
N
Parameter number
The parameter # number is shown with the value following N.
A
Axis number
For axis data, the axis number is shown with the value following A.
The first axis will be AI.
T
Axis system number For data per system, the system number is shown with the value
following T.
(1st system: T1, PLC axis: T3)
(Note)
Only the 1st system is shown for EZMotion-NC E60/E68.
P
Parameter data
The parameter data is shown with the value following P.
The following types of data format are used according to parameter type and display method.
(The address order in one block must use the following format.)
1) Common parameter (one data item per one # number)
N 1 0 8 4 P 0 . 0 0 1 ;
Parameter setting value
Parameter # number
(1) The output parameter setting value is the same format as the screen display.
2)
Axis
parameter
N 2 0 0 1 A 1 P 1 0 0 0 0 ;
Parameter setting value
Axis number 1 to 4
# number on screen
(1) When multiple axes are displayed on one screen
The parameter data for when the parameters for multiple axes are displayed on one screen
are output per axis.
[Output
example]
:
N2001A1P120000 ;
N2002A1P4000 ;
N2003A1P21 ;
:
N2001A2P12000 ;
N2002A2P4000 ;
N2003A2P21 ;
:
Axis 2 data
Axis 1 data
Summary of Contents for EZMotion-NC E60 Series
Page 1: ......
Page 15: ...I OPERATION SECTION ...
Page 361: ...II MACHINE OPERATION MANUAL ...
Page 399: ...III SETUP ...
Page 472: ...IV APPENDIXES ...
Page 510: ......