2. Monitor
2.1 POSITION
I
-25
(5) The set data will be canceled if screen change is executed during manual numeric command
operation.
(6) If operations in which manual numeric commands are carried out (M, S, T keys) are attempted
when the manual numeric command protect function is valid, the error message "E05 NOT
ACCEPTABLE" will occur.
2.1.4 Displaying Automatic Operation Program
(1) Displaying the operation program during automatic operation
During memory, tape, or MDI operation, up to four blocks of the specified program are displayed.
The block being executed or the completed block will display at the top line.
(2) Displaying the operation program after SEARCH
The head block of the operation searched program is displayed at the line of the next command.
(3) Displaying the operation program at branch to or at return from subprogram
When a branch command (M98) block is executed, the subprogram is immediately displayed.
When a return command (M99) block is executed, the main program is immediately displayed.
(4) Difference between one block of work program and one execution block
1) A block containing only EOB or only a comment statement is not interpreted as one execution
block. Instead it is processed as one block together with the next block.
2) A block that does not contain a movement command or MST command, such as a variable
command, is not interpreted as one execution block. Instead, the program up to the block
containing a movement command or MST command is handled in the same manner as one
block.
(Note)
When a parameter "MACRO SINGLE" is ON, a variable command block is regarded as an
execution block.
Summary of Contents for EZMotion-NC E60 Series
Page 1: ......
Page 15: ...I OPERATION SECTION ...
Page 361: ...II MACHINE OPERATION MANUAL ...
Page 399: ...III SETUP ...
Page 472: ...IV APPENDIXES ...
Page 510: ......