4.5.3 Restoring Individual Data
The parameters are restored from the backup cassette to the NC with the following steps.
"EMG EMERGENCY" will appear at the
operation message area.
WORK PROCESS
I/O PAR
SETUP
MENU
#( ) (
)
EMG EMERGENCY
Execute emergency stop.
(1)
#(2) (
)
PLC STOP Y/N
EMG EMERGENCY
Input "2", "ALL1" at the setting area
# ( ) ( ), and press the
INPUT
key.
(2)
WORK PROCESS
I/O PAR
SETUP
MENU
"PLC STOP Y/N" will appear at the
message area.
The error "E330 Maintenance Cassette
error" will occur if the backup cassette is
not mounted.
#(2) (
Y)
RESTORE EXEC Y/N
EMG EMERGENCY
Input "Y" at the setting area ( ),
and press the
INPUT
key.
(3)
"RESTORE EXEC Y/N" will appear at
the message area.
WORK PROCESS
I/O PAR
SETUP
MENU
Input "Y" at the setting area ( ),
and press the
INPUT
key.
(4)
#(2) (
Y)
RESTORE EXECUTION
EMG EMERGENCY
(a) The message "RESTORE EXECUTION"
will appear while the parameters are
being restored.
WORK PROCESS
I/O PAR
SETUP
MENU
(b) The message "RESTORE COMPLETE" will
appear when the restoration is completed.
#( ) (
)
RESTORE COMPLETE
EMG EMERGENCY
WORK PROCESS
I/O PAR
SETUP
MENU
(Note 1)
When ALL2 and ALL3 are input instead of ALL 1, only the data for the corresponding class
will be restored.
(Note 2)
Other screens cannot be shifted to during this operation.
(Note 3)
If the PLC is already stopped, step (3) is skipped.
The PLC will not start running even when the operations are completed.
(Note 4)
If the
INPUT
key is pressed without inputting anything at the "~Y/N" display, the error "E01
SETTING ERROR" will occur.
(Note 5)
Even if the PLC RUN/STOP changeover is prohibited (R2925/bit2 ON), the PLC will stop
with step (3).
(Note 6)
The "ALL1" settings are restored even if "PARAM" is input.