6. Operation Panel Switch Functions
6.6 Override Cancel
II
-19
6.6 Override Cancel
(1) When the OVERRIDE CANCEL switch is turned ON, the programmed F command value takes
precedence over the override value set by using the FEED RATE OVERRIDE switch.
(2) It is not effective for manual override.
6.7 Optional Stop
(1) If M01 is programmed, the machine automatically stops by turning ON the OPTIONAL STOP
switch. When the switch is OFF, M01 is ignored and the machine does not stop.
(2) The machine stops after the M01 block is executed.
6.8 Optional Block Skip
When the OPTIONAL BLOCK SKIP switch is turned ON, a block which begins with a slash ( / ) is
skipped; when the switch is OFF, the block is executed. This enables the operator to specify whether or
not a block beginning with a slash ( / ) code is executed.
(Example)
To work two parts as illustrated below, if the following program is prepared and work is
made by turning ON the OPTIONAL BLOCK SKIP switch, part (1) is provided; if work is
made by turning OFF the switch, part (2) is provided:
Program
N1G54
;
N2G90G81X50. Z-20. R3. F100 ;
/N3X30.
;
N4X10.
;
N5G80
;
M02
;
N4
N4
N2
N3
N2
Part (1)
Switch
ON
Part (2)
Switch OFF