background image

1

  CONSUMER MANUAL – 

DP C18.CAN

CONTENT

CONTENT

UB400 DISPLAY MANUAL

1 Important Notice 

 

2

2 Introduction 

  3

3 Product Description 

  4

3.1   Performance 

  4

3.2   Functions Overview 

  4

4 Indication Area 

  5

5 Button Definition 

  5

6 Normal Operation 

  6

6.1   Power ON/OFF 

  6

6.2   Power assistance level selection 

  6

6.3   Mileage mode and Speed mode 

  6

6.4   Headlight /backlight 

  7

6.5   Walk assistance mode 

  8

6.6   “SERVICE” indication 

  8

7 User Setting

9

7.1   “SETTING” interface

9

7.2   “Display setting” interface

9

7.3   “Information” interface 

13

8 Error Code Definition 

15

9 Maintenance 

18

FiSHAW 2020

Summary of Contents for UB400

Page 1: ...ion Area 5 5 Button Definition 5 6 Normal Operation 6 6 1 Power ON OFF 6 6 2 Power assistance level selection 6 6 3 Mileage mode and Speed mode 6 6 4 Headlight backlight 7 6 5 Walk assistance mode 8 6 6 SERVICE indication 8 7 User Setting 9 7 1 SETTING interface 9 7 2 Display setting interface 9 7 3 Information interface 13 8 Error Code Definition 15 9 Maintenance 18 FiSHAW 2020 ...

Page 2: ...d to be completely waterproof for riding in rainy days do not let this product soak in water or use in water Do not clean the Pedelec with a steam jet high pressure cleaner or water hose Water may seep into the electrics or drive and destroy the equipment Please use this product with care and wit hout strong impact Do not use thinner or other solvents to clean any of the HMI Such substances may da...

Page 3: ...CAN The housing material is PC the window is high hardness glass as following Cable label identification is as following DPC18CP10101 0 PD051205 Note Contents in Label part are important information of this product Please keep them properly for updating of software or providing after sales service FiSHAW 2020 ...

Page 4: ...ation for the headlight light sensation Brightness adjustment for backlight Indication of power assistance level Motor output power and output current indication Time indication for single riding Trip indication including single trip distance total distance and remaining distance Walk assistance model Support level setting Indication for consumption of energy CALO RIES Note If the display has this...

Page 5: ...peed AVG remaining distance RANGE energy consumption CALORIES time TIME Note same function needs the Controller supports 6 Indication for the current remaining capacity of battery 7 Voltage indication percentage indication 8 Speed digital indication 9 Power indication current indication with scale 10 Power assistance level indication Walk assistance Note symbol means Walk assistance model 11 Data ...

Page 6: ... power on briefly press or 0 5S to switch the assistance level the number of assistance level needs to be adapted to controller The lowest level is Level 0 the highest Level is 5 On the default is Level 1 0 means no power assistance The interface is as following 6 3 Mileage mode and Speed mode Briefly press 0 5s to view the mileage and speed information 1 System with torque sensor circularly show ...

Page 7: ...2S again to turn off the backlight and the headlight The brightness of back light can be set in function Brightness If the display is turned on in a dark environment the display backlight headlight will be turned on automatically If the display backlight headlight are turned off manually they also need to be turned on manually afterwards FiSHAW 2020 ...

Page 8: ...l stop this if no any operations within 5s will automatically return to 0 level That is stopped from the Walk assistance mode as following 6 6 SERVICE indication HMI will prompt for maintenance according to the mileage and battery charger times When mileage exceeds 5000km and the Service function is enabled the SERVICE indication will be displayed every time This function can be set in the interfa...

Page 9: ...0s the set interface will be exited and no any dates are saved as following 7 2 Display setting interface In SETTING interface briefly press 0 5S or to select Display setting and then briefly press 0 5S to confirm and enter into Display setting There are thirteen options in this interface 7 2 1 Unit set unit for km mile Briefly press 0 5S or to select Unit and then briefly press 0 5S to enter into...

Page 10: ...Off and then briefly press 0 5S to enter into the interface Select the automatic Off time as OFF 9 8 7 6 5 4 3 2 1 OFF means don t turn off The unit is in minute And then briefly press 0 5S to save and exit back to Auto Off interface then briefly press 0 5S for two times to exit or you can also select BACK EXIT to exit back to the main interface 7 2 5 MAX PAS set riding mode Briefly press 0 5S or ...

Page 11: ...ensitivity and then briefly press 0 5S to enter into the interface Select the level of the light sensitivity as 0 1 2 3 4 5 OFF OFF means close the function And then briefly press 0 5S to save and exit back to AL Sensitivity interface then briefly press 0 5S for two times to exit or you can also select BACK EXIT to exit back to the main interface 7 2 10 Password set access password Briefly press 0...

Page 12: ... password in the interface And the following step is same with starting password After changing the password it will exit automatically back to the original interface within two seconds Briefly press for two times 0 5S to exit back to the main interface or select BACK EXIT to exit back to main interface Cancel password access In Start PassWord interface to select OFF and then briefly press 0 5S Th...

Page 13: ...fly press 0 5S for two times to exit back or select BACK EXIT to exit back to the main interface 7 3 2 Check Battery Info Briefly press 0 5S or to select Bat tery Info and briefly press 0 5S to enter into and check content This moment select Next Page and briefly press 0 5S to check content at next page As follow ing list Display content Explanation TEMP Current temperature TotalVolt Battery volta...

Page 14: ...n briefly press 0 5S two times to exit back to main interface or select BACK EXIT to exit back to the main interface 7 3 5 Check Torque Info Briefly press 0 5S or to select Torque Info and then briefly press 0 5S to confirm If no data is detected it displays and then briefly press 0 5S two times to exit back to main interface or select BACK EXIT to exit back to the main interface 7 3 6 Check Error...

Page 15: ...ur dealer or professional 08 Fault with hall sensor signal inside of motor Stop to ride and bring your Pedelec to your dealer or to a specialist to have the error fixed 09 Fault with motor phase lines Stop to ride and bring your Pedelec to your dealer or to a specialist to have the error fixed 10 The temperature inside of motor reaches to the max protection value Stop to ride and make the e bike f...

Page 16: ...e contact your dealer or professional 33 Brake detection circuit is fault Stop to ride and bring your Pedelec to your dealer or to a specialist to have the error fixed 35 Detection circuit for 15V is fault Stop to ride and bring your Pedelec to your dealer or to a specialist to have the error fixed 36 Detection circuit for button is fault Stop to ride and bring your Pedelec to your dealer or to a ...

Page 17: ...ttery if the problem is not eliminated please contact your dealer or professional 48 SOC of battery is too low Replace the battery if the problem is not eliminated please contact your dealer or professional 61 Gear shifter stuck Replace the gear shifter if the problem is not eliminated please contact your dealer or professional 62 Gear shifter cannot release Replace the gear shifter if the problem...

Page 18: ...hard objects to operate on the button and HMI s Windows Do not use high pressure water spray in any position of product If storing this production for a long period please turn it off do not leave it near sour ces of heat such as heaters When the production is damaged due to im proper use and maintenance will not enjoy after sales service obligations FiSHAW 2020 ...

Page 19: ...19 ERROR CODE DEFINITION CONSUMER MANUAL DP C18 CAN FiSHAW 2020 ...

Page 20: ...20 CONSUMER MANUAL DP C18 CAN FiSHAW 2020 ...

Reviews: