7. Diagnosis
7.12 PLC Signal Trace
I
-297
7.12.2 Device Monitor Screen
When the
NEXT
PAGE
key is pressed in the "DEVICE SET" screen, the "DEVICE MONITOR" screen is
displayed.
Tracing status of the device set in the "DEVICE SET" screen can be monitored. The latest 256
sampling data can be monitored for each device.
[DEVICE MONITOR] ALARM/DIAG13. 2/2
#P:RUN
#I:STP
<TRIGGER INFORMATION>
TRACE STOP TRIG. HIT 00/06/05 13:35:50
<DEVICE> <DATA>
0 10 20 30 40 50 60
X0000 __________________1111111111_________1
1
11111111111111111_____
X0180 11111111111111________________________
_
________11111111111111
Y0000
______________________________________
1
1111111111111111111111
G0100
_______1111111___________1111111111111
1
______________________
M1000 11111111111111111111111111111111111111
1
1111111111111111111111
M1200 111111111111111111____________________
_
________11111111111111
R1900 ooooooooooooooooooo1111111111111111111
1
111ooooooooooooooooooo
D0700 1111111111111111111111111111111111oooo
o
oooooooooooooooooooooo
#( )
S.TRACE
MENU
(1) Trace RUN/STOP
(a) Set #(P) and press the
INPUT
key to erase the previous trace data and start tracing.
(b) Set #(I) and press the
INPUT
key to stop tracing regardless of trigger conditions and trigger state.
(c) "#1: STOP" is highlighted when trace is stopped upon establishment of trigger conditions.
Also, when #(P)+
INPUT
key is pressed in this state, trace can be started with the same trigger
conditions.
(2) Trace status display
The statuses of trace execution are as shown below.
Display Status
TRACE RUN
Set device is being traced.
TRACE STOP
Trace is ended.
Summary of Contents for EZMotion-NC E60 Series