8
Basic drive functions (MCK)
8.8
Positioning
584
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.8.2
Parameter setting
Short overview of parameters for "positioning" mode:
Parameters
Info
Lenze setting
Value Unit
MCK: Positioning setting
Bit coded
Profile 1 ... 15: Mode
1: absolute (beeline)
Profiles 1 ... 15: Position
360.0000 unit
Profile 1 ... 15: Speed
360.0000 unit/s
Profile 1 ... 15: Accel.
720.0000 unit/s2
Profile 1 ... 15: Decel.
720.0000 unit/s2
Profile 1 ... 15: Final speed
0.0000 unit/s
Profiles 1 ... 15: S-ramp time
0.000 s
Profiles 1 ... 15: Sequence profile
0
Profile 1 ... 15: TP profile
(from version 06.00.00)
0
Profile 1 ... 15: TP signal source
(from version 06.00.00)
3: TP-DigIn3
MCK: Resp. to invalid PosModus
4: WarningLocked
MCK: Resp. to invalid profile data
4: WarningLocked
MCK: Resp. to invalid profile no.
4: WarningLocked
MCK: React target out of travel range
4: WarningLocked
MCK: Curr. feed
- units
MCK: Curr. set position
- units
MCK: Curr. actual position
- units
MCK: Curr. following error
- units
MCK: Positioning accuracy
- units
MCK: Target position
- units
Max. traversing speed 100%_C11
- units/s
MCK: Max. traversing distance
- units
MCK: Current pos profile number
-
Greyed out = display parameter
Note!
For trouble-free operation, the
(at least gearbox factor and feed
constant) must also be set correctly!