15
Parameter reference
15.2
Parameter list
1064
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01134
C01135
C01136
C01138
Parameter | Name:
C01134 | LS_RetainData: 16bit data
Data type: UNSIGNED_16
Index: 23441
d
= 5B91
h
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C01134/1
0
: wValue1
C01134/2
0
: wValue2
C01134/3
0
: wValue3
C01134/4
0
: wValue4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01135 | LS_RetainData: 32bit data
Data type: INTEGER_32
Index: 23440
d
= 5B90
h
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C01135/1
0
: dnValue1
C01135/2
0
: dnValue2
C01135/3
0
: dnValue3
C01135/4
0
: dnValue4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01136 | LS_RetainData: Bool data
Data type: UNSIGNED_8
Index: 23439
d
= 5B8F
h
Selection list
Info
0 False
1 True
Subcodes
Lenze setting
Info
C01136/1
0: FALSE
: bValue1
C01136/2
0: FALSE
: bValue2
C01136/3
0: FALSE
: bValue3
C01136/4
0: FALSE
: bValue4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01138 | L_Transient 1-4: Function
Data type: UNSIGNED_8
Index: 23437
d
= 5B8D
h
From version 04.00.00
Selection of edge evaluation
Selection list
0 High edge
1 Low edge
2 High and low edge