15
Parameter reference
15.2
Parameter list
1086
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01251
C01252
8 M-Limit: Stop
Detection of torque limit, tolerance time is running
9 Reference: Search
Search travel until reference initiator
10 Reference: Stop
Stop when reference initiator has been detected
11 Reference: Offset
Travel offset path active
12 Reference: Sequence profile
Travel sequence profile after homing
13 Reference: Position
Travel to home position
14 Reference: Abort
Homing process aborted
15 Finish
Homing process executed
Subcodes
Info
C01248/1
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01248 | MCK: Ref. step
Data type: UNSIGNED_8
Index: 23327
d
= 5B1F
h
Parameter | Name:
C01251 | MCK: Acceleration stop
Data type: INTEGER_32
Index: 23324
d
= 5B1C
h
Acceleration parameter for stop
Setting range
(min. value | unit | max. value)
-214748.3647
units/s2
214748.3647
Subcodes
Lenze setting
Info
C01251/1
720.0000 units/s2
MCK: Stop: Decel.
• Deceleration for setpoint speed ramp-down to
standstill.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000
Parameter | Name:
C01252 | MCK: S-ramp times stop
Data type: UNSIGNED_16
Index: 23323
d
= 5B1B
h
S-ramp times for stop
• Setting "0 s"
≡
no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01252/1
0.000 s
MCK: Stop: S-ramp time
• S-ramp time for setpoint speed ramp-down to
standstill.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000