Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
817
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00010
C00011
3016 SwitchPos|Terminal 16
Application: Switch-off positioning
I/O level: "Terminal 16" control mode
3020 SwitchPos|Keypad
Application: Switch-off positioning
I/O level: "Keypad" control mode
3021 SwitchPos|PC
Application: Switch-off positioning
I/O level: "PC" control mode
3030 SwitchPos|CAN
Application: Switch-off positioning
I/O level: "CAN" control mode
3040 SwitchPos|MCI
Application: Switch-off positioning
I/O level: "MCI" control mode
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00008 | Original application|control source
Data type: UNSIGNED_16
Index: 24567
d
= 5FF7
h
Parameter | Name:
C00010 | AIN1: Characteristic
Data type: INTEGER_16
Index: 24565
d
= 5FF5
h
From version 04.00.00
Signal adaptation via characteristic
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00010/1
0.00 %
AIN1: (+y0) = min
C00010/2
0.00 %
AIN1: (+x0) = Dead band
C00010/3
0.00 %
AIN1: (-y0) = (-min)
C00010/4
0.00 %
AIN1: (-x0) = (-Dead band)
C00010/5
100.00 %
AIN1: (+ymax)
C00010/6
100.00 %
AIN1: (+xmax)
C00010/7
100.00 %
AIN1: (-ymax)
C00010/8
100.00 %
AIN1: (-xmax)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00011 | Appl.: Reference speed
Data type: UNSIGNED_16
Index: 24564
d
= 5FF4
h
Setting the reference speed
• In the inverter, all speed-related signals are processed to one reference variable in percent.
• Set a reference speed here that corresponds to 100 %.
• The frequency that corresponds to the set reference speed is displayed in
Note:
This is not a maximum limitation!
All values in percent in the inverter may be in a range of 0 ... 199.99 %.
Recommendation:
Deactivate the torque feedforward control for the speed setpoint in
if the reference speed
is 5
times higher than the rated motor speed
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
60000
1500 rpm
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1