Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
815
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00008
20 Keypad
The technology application is controlled via the keypad.
21 PC
The technology application is controlled via the "Free
parameters" of the inverter (PC control).
30 CAN
The technology application is controlled by means of
CAN-PDOs via the system bus "CAN on board".
40 MCI
The technology application is controlled by means of
MCI-PDOs via the MCI-interface of an attached
communication module (e.g. PROFIBUS).
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00007 | Control mode
Data type: UNSIGNED_16
Index: 24568
d
= 5FF8
h
Parameter | Name:
C00008 | Original application|control source
Data type: UNSIGNED_16
Index: 24567
d
= 5FF7
h
Display of the originally selected technology application and the originally selected control mode.
• This parameter shows the selection that was set with
before a change in the I/O level or the
application level was carried out.
• For diagnostic purposes, this display serves to determine whether there is a standard interconnection in the
inverter or a change carried out by the user.
Selection list
(read only)
Info
0 Free|Free
Application: Interconnection has been changed.
I/O level: Interconnection has been changed.
10 Free|Terminal0
Application: Interconnection has been changed.
I/O level: "Terminals 0" control mode
12 Free|Terminal2
Application: Interconnection has been changed.
I/O level: "Terminal 2" control mode
14 Free|Terminal11
Application: Interconnection has been changed.
I/O level: "Terminal 11" control mode
16 Free|Terminal 16
Application: Interconnection has been changed.
I/O level: "Terminal 16" control mode
20 Free|Keypad
Application: Interconnection has been changed.
I/O level: "Keypad" control mode
21 Free|PC
Application: Interconnection has been changed.
I/O level: "PC" control mode
30 Free|CAN
Application: Interconnection has been changed.
I/O level: "CAN" control mode
40 Free|MCI
Application: Interconnection has been changed.
I/O level: "MCI" control mode
1000 Speed|Free
Application: Actuating drive speed
I/O level: Interconnection has been changed.
1010 Speed|Terminal0
Application: Actuating drive speed
I/O level: "Terminals 0" control mode
1012 Speed|Terminal2
Application: Actuating drive speed
I/O level: "Terminal 2" control mode
1014 Speed|Terminal11
Application: Actuating drive speed
I/O level: "Terminal 11" control mode
1016 Speed|Terminal16
Application: Actuating drive speed
I/O level: "Terminal 16" control mode
1020 Speed|Keypad
Application: Actuating drive speed
I/O level: "Keypad" control mode