15
Parameter reference
15.2
Parameter list
828
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00071
C00072
C00073
Subcodes
Lenze setting
Info
C00070/1
power-related (see
C00070/2
power-related (see
: Vp speed controller
C00070/3
power-related (see
: Vp speed controller
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00070 | Vp speed controller
Data type: UNSIGNED_16
Index: 24505
d
= 5FB9
h
Parameter | Name:
C00071 | Ti speed controller
Data type: UNSIGNED_16
Index: 24504
d
= 5FB8
h
Reset time Ti of the speed controller for different motor control types
Setting range
(min. value | unit | max. value)
0.0
ms
6000.0
Subcodes
Lenze setting
Info
C00071/1
100.0 ms
C00071/2
50.0 ms
: Ti speed controller
C00071/3
50.0 ms
: Ti speed controller
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00072 | SC: Tdn speed controller
Data type: UNSIGNED_16
Index: 24503
d
= 5FB7
h
Differential time constant Tdn of the speed controller for servo control (
) and sensorless control for synchronous
motors (
)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
3.00
0.00 ms
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00073 | Imax/M controller gain
Data type: UNSIGNED_16
Index: 24502
d
= 5FB6
h
Amplification factor Vp of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0.00
100.00
Subcodes
Lenze setting
Info
C00073/1
power-related (see
: Vp Imax controller
• After the motor to be used has been selected from the
motor catalogue, the suitable value can be entered
automatically.
C00073/2
power-related (see
: Vp torque controller
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100