15
Parameter reference
15.2
Parameter list
830
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00078
C00079
C00080
Parameter | Name:
C00078 | SC: Tn field controller
Data type: UNSIGNED_16
Index: 24497
d
= 5FB1
h
Reset time Tn of the field controller for servo control (
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
ms
6000.0 power-related (see
)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00079 | SC: Settings
Data type: UNSIGNED_8
Index: 24496
d
= 5FB0
h
Configuration of different options for servo control (
) and sensorless control for synchronous motors (
)
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00079/1
0: Off
: Current controller - feedforward control
• Please observe the notes regarding this function in
the chapter "
Feedforward control of the current
"!
C00079/2
1: On
: Adapt. VP in the field weakening range
• Speed-dependent adaptive field weakening
controller.
C00079/3
0: Off
: n-ctrl anti-wind-up
• "Anti-wind-up" effect of the speed controller in case
of an output voltage limitation in the field weakening
range.
C00079/4
1: On
Field weakening for synchronous motors
•
From version 11.00.00
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00080 | Override point of field weakening
Data type: INTEGER_16
Index: 24495
d
= 5FAF
h
Offset of the override point for field weakening
• In the V/f characteristic control mode (
), the stall protection function or the max. permissible current in
the field weakening range can be adapted.
Setting range
(min. value | unit | max. value)
Lenze setting
-500
Hz
500
0 Hz
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1