C01094
C01095
C01098
Parameter | Name:
C01094 - LS_ParReadWrite 1-6: Numerator
Data type: INTEGER_16
Index: 23481
d
= 5BB9
h
From version 06.00.00
: Factor (numerator) for internal conversion in arithmetic modes 1 ... 3.
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C01094/1
1
: Numerator
C01094/2
1
: Numerator
C01094/3
1
: Numerator
C01094/4
1
: Numerator
C01094/5
1
: Numerator
C01094/6
1
: Numerator
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01095 - LS_ParReadWrite 1-6: Denominator
Data type: INTEGER_16
Index: 23480
d
= 5BB8
h
From version 06.00.00
: Factor (denominator) for internal conversion in arithmetic modes 1 ... 3.
Setting range
(min. value | unit | max. value)
1
32767
Subcodes
Lenze setting
Info
C01095/1
1
: Denominator
C01095/2
1
: Denominator
C01095/3
1
: Denominator
C01095/4
1
: Denominator
C01095/5
1
: Denominator
C01095/6
1
: Denominator
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01098 | LS_ParReadWrite 1-6: Configuration
Data type: UNSIGNED_16
Index: 23477
d
= 5BB5
h
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Keeping the value
Bit 1 Keeping the value in the event of an
error
Bit 2
Reserved
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved