15
Parameter reference
15.2
Parameter list
1140
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02811
C02812
C02813
Parameter | Name:
C02811 | TP: Sensor delay
Data type: UNSIGNED_16
Index: 21764
d
= 5504
h
From version 06.00.00
Setting range
(min. value | unit | max. value)
0
μ
s
6999
Subcodes
Lenze setting
Info
C02811/1
0
μ
s
Reserved
C02811/2
0
μ
s
Reserved
C02811/3
0
μ
s
TPDigIn3: Sensor delay
C02811/4
0
μ
s
TPDigIn4: Sensor delay
C02811/5
0
μ
s
TPDigIn5: Sensor delay
C02811/6
0
μ
s
TPDigIn6: Sensor delay
C02811/7
0
μ
s
TPDigIn7: Sensor delay
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C02812 | TP: Position offset
Data type: INTEGER_32
Index: 21763
d
= 5503
h
From version 06.00.00
Setting range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Lenze setting
Info
C02812/1
0.0000 units
Reserved
C02812/2
0.0000 units
Reserved
C02812/3
0.0000 units
TPDigIn3: Pos offset
C02812/4
0.0000 units
TPDigIn4: Pos offset
C02812/5
0.0000 units
TPDigIn5: Pos offset
C02812/6
0.0000 units
TPDigIn6: Pos offset
C02812/7
0.0000 units
TPDigIn7: Pos offset
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000
Parameter | Name:
C02813 | TP: Pos. window start
Data type: INTEGER_32
Index: 21762
d
= 5502
h
From version 06.00.00
Setting range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Lenze setting
Info
C02813/1
-214748.3647 units
TPDigIn3: Window start
C02813/2
-214748.3647 units
TPDigIn4: Window start
C02813/3
-214748.3647 units
TPDigIn5: Window start
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000