15
Parameter reference
15.2
Parameter list
946
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00653
C00654
C00658
Subcodes
Lenze setting
Info
C00650/1
0: nOut_a = nIn1_a
: Function
C00650/2
0: nOut_a = nIn1_a
: Function
C00650/3
0: nOut_a = nIn1_a
: Function
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00650 | L_Arithmetik 3-5: Function
Data type: UNSIGNED_8
Index: 23925
d
= 5D75
h
Parameter | Name:
C00653 | Sensibility - Setpoint feedforward control
Data type: UNSIGNED_8
Index: 23922
d
= 5D72
h
From version 12.00.00
Selection of the sensitivity of the differential setpoint feedforward control
• Depending on the selection, the number of indicated higher-order bits is evaluated.
Note:
The most significant bit determines the sign of the value, the remaining bits determine the numerical value.
Selection list
Info
0 Inactive
1 15 bits
Bit 0 ... bit 14 are evaluated
2 14 bits
Bit 0 ... bit 13 are evaluated
3 13 bits
Bit 0 ... bit 12 are evaluated
4 12 bits
Bit 0 ... bit 11 are evaluated
5 11 Bit
Bit 0 ... bit 10 are evaluated
6 10 Bit
Bit 0 ... bit 9 are evaluated
7 9 Bit
Bit 0 ... bit 8 are evaluated
Subcodes
Lenze setting
Info
C00653/1
0: Inactive
Sensibility - Setpoint feedforward control
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00654 | Source of diff. setpoint feedforward control
Data type: UNSIGNED_8
Index: 23921
d
= 5D71
h
From version 12.00.00
Selection of the process signal for the setpoint feedforward control
Selection list
Info
0 nSpeedSetValue_a
1 nSpeedSetValueInertia_a
The new process signal
nSpeedSetValueInertia_a
at
SB
can be used to define any input
value (e.g. position or process controller setpoint) for
torque feedforward control.
Subcodes
Lenze setting
Info
C00654/1
0: nSpeedSetValue_a
Source of diff. setpoint feedforward control
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00658 | PRBS amplitude
Data type: INTEGER_16
Index: 23917
d
= 5D6D
h
This code is for device-internal use only and must not be written to by the user!