15
Parameter reference
15.2
Parameter list
1094
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01309
C01350
C01351
Parameter | Name:
C01309 | Profile data: TP signal source
Data type: UNSIGNED_8
Index: 23266
d
= 5AE2
h
From version 06.00.00
Selection of the touch-probe signal sources for profile 1 ... 15
• Only relevant for positioning modes with touch-probe.
Selection list
3 TP-DigIn3
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6
7 TP-DigIn7
Subcodes
Lenze setting
Info
C01309/1
3: TP-DigIn3
Profiles 1 ... 15: Sequence profile
C01309/...
C01309/15
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01350 | ACDrive: Drive mode
Data type: UNSIGNED_8
Index: 23225
d
= 5AB9
h
Selection list
1 Speed mode
3 Torque mode
Subcodes
Lenze setting
Info
C01350/1
1: Speed mode
ACDrive: Drive mode
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01351 | ACDrive: Control word
Data type: UNSIGNED_16
Index: 23224
d
= 5AB8
h
From version 13.00.00
Display of the "AC Drive Profile" control word for the inverter
• Detailed information on the "AC Drive Profile" can be found in the EtherNet/IP™ communication manual.
Actuating drive speed (AC Drive Profile)
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Run Forward
Relationships between Run1 and Run2 and trigger
events can be found in the chapter "
".
Bit 1 Run Backward
Bit 2 Fault Reset
0->1
≡
Reset error
0
≡
No response
Bit 3 Reserved
Bit 4 Reserved
Bit 5 NetCtrl
Run/Stop control:
0
≡
via local setting in the device or terminal
1
≡
via fieldbus (e.g. by the scanner)