3.7.3
Parameterising the motor control
1. Select the
Application parameters
tab from the
Workspace
.
The motor control parameters, among other things, can be found on the left:
2. In the
Motor control
list field (
), select the desired motor control.
3. Adapt the motor control parameters:
Related topics:
Parameters
Lenze setting
Info
Value Unit
V/f base frequency
(
)
50.0 Hz
Adapting the V/f base frequency (
Imax in motor mode
(
)
47.00 A
Optimising the Imax controller (
Vmin boost
(
)
1.60 %