17
Function library
17.1
Function blocks | L_PhaseIntK_1
1471
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.137
L_PhaseIntK_1
This FB can integrate a speed or a velocity to an angle (path). The FB can also detect a relatively
completed distance.
• The integrator can take max. ±32000 encoder revolutions.
Inputs
Outputs
Parameters
Designator
Data type
Information/possible settings
nIn_v
INT
Selection of the actual speed
• 16384
≡
15000 rpm
bLoad
BOOL
Load angle integrator with starting value and reset status signal
TRUE Angle integrator is loaded with the value at
dnSet_p
and
bStatus
is
reset to FALSE.
dnSet_p
DINT
Starting value for angle integrator
Designator
Data type
Value/meaning
dnOut_p
DINT
Angle output signal
• 65536 [incr.]
≡
1 encoder revolution
• Overflow is possible (display via
bStatus
)
bStatus
BOOL
Status signal "Overflow occurred/distance processed"
• Status signal can be reset via
bLoad
.
TRUE Overflow has occurred or distance is processed.
Parameters
Possible settings
Info
Function
0 Loading with level
Load integrator with TRUE level at
the input
bLoad
(Lenze setting)
1 Loading with edge
Load integrator with FALSE/TRUE
edge at the input
bLoad
.
2 Loading with level + reset
Load integrator when reaching the
comparison value or with TRUE level
at the input
bLoad
.
0
2000000000 Comparison value
• Is valid for both the positive and
the negative value range.
• Lenze setting: 0
/B3KDVH,QW.B
GQ2XWBS
Q,QBY
E/RDG
GQ6HWBS
&
& &RPSDUHYDOXH
)XQFWLRQ
E6WDWXV