8
Basic drive functions (MCK)
8.12
Holding brake control
608
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.12.2
Parameter setting
How to go to the parameterisation dialog of the holding brake control:
1. »Engineer« Go to the
Project view
and select the 8400 HighLine inverter.
2. Select the
Application parameters
tab from the
Workspace
.
3. Go to the
Overview
dialog level and click the "
Basic functions
" button.
4. Go to the
Overview
Basic functions
dialog box and click the
Holding brake control
button.
Short overview of parameters for holding brake control:
Danger!
A faultless holding brake control function requires a correct setting of the different
deceleration times in the following parameters!
A wrong setting of the delay times can cause a faulty control of the brake!
Parameters
Info
Lenze setting
Value Unit
Holding brake: Operating mode
0: Brake control off
Holding brake: Switching threshold
5.00 %
Holding brake: Hyst. release
1.00 %
Holding brake: Hyst. close
1.00 %
Holding brake: FF control starting value 1
0 %
Holding brake: FF control starting value 2
0 %
Holding brake: Setting
0
Greyed out = display parameter