15
Parameter reference
15.2
Parameter list
1072
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01221
Bit 5 Maximum jerk
1
≡
The maximum jerk is calculated based on the
acceleration and S-ramp time of the current profile and
the sequence profile. This is then used in an accelerated
drive for reducing the acceleration to 0 or for
acceleration of the sequence profile.
Setting or activation of maximum jerk for traversing
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C01220/1
0x0000
MCK: Ref. setting
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C01220 | MCK: Ref. setting
Data type: UNSIGNED_16
Index: 23355
d
= 5B3B
h
Parameter | Name:
C01221 | MCK: Ref. mode
Data type: UNSIGNED_8
Index: 23354
d
= 5B3A
h
Selection of the homing mode.
Selection list
(Lenze setting printed in bold)
Info
4 >_Rp_<_TP
Positive direction - reversing on pre-stop mark (pos.
edge) - to touch probe
•
From version 14.00.00
5 <_Rp_>_TP
Negative direction - reversing on pre-stop mark (pos.
edge) - to touch probe
•
From version 14.00.00
6 >_Rn_>_TP
Positive direction - via pre-stop mark (neg. edge) -
continuing in positive direction - to touch probe
7 <_Rn_<_TP
Negative direction - via pre-stop mark (neg. edge) -
continuing in negativee direction - to touch probe
8 >_TP
Positive direction - to touch probe
9 <_TP
Negative direction - to touch probe
10 >_Lp_<_TP
Positive direction - reversing on pos. limit switch - to
touch probe
11 <_Ln_>_TP
Negative direction - reversing on neg. limit switch - to
touch probe
12 >_Lp
Positive direction - to pos. limit switch