Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1053
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01079
C01080
C01081
C01082
Parameter | Name:
C01079 | L_DFRFG_1: Synchronisation window
Data type: UNSIGNED_16
Index: 23496
d
= 5BC8
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0
Incr.
65535
Subcodes
Lenze setting
Info
C01079/1
100 incr.
: Synchronisation window (position)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01080 | L_DFRFG_1: Offset
Data type: INTEGER_32
Index: 23495
d
= 5BC7
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
Subcodes
Lenze setting
Info
C01080/1
0 incr.
: Offset
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01081 | L_DFRFG_1: Sync. direction / TP function
Data type: UNSIGNED_8
Index: 23494
d
= 5BC6
h
From version 11.00.00
Selection list
1 cw/ccw - without TP
2 cw - without TP
3 ccw - without TP
4 cw/ccw - with TP
5 cw - with TP
6 ccw - with TP
Subcodes
Lenze setting
Info
C01081/1
1: cw/ccw - without TP
: Sync. direction / TP function
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01082 | LS_WriteParamList: Execute Mode
Data type: UNSIGNED_8
Index: 23493
d
= 5BC5
h
From version 04.00.00
: Selection of the activation method
Selection list
(Lenze setting printed in bold)
Info
0 by Execute
The writing of the parameter list is activated by a FALSE/
TRUE edge at the
bExecute
input.
1 by Input Select
The writing of the parameter list is carried out if a change
is made at the select inputs and if the inverter is
initialised.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1