Motor control (MCTRL)
5.1
Motor selection/Motor data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.1
Motor selection/Motor data
The motor data term comprises all parameters that only depend on the motor and that only
characterise the electrical behaviour of the machine. The motor data are independent of the
application in which the inverter and the motor are used.
Proceed as follows to open the dialog for parameterising the motor data:
1. »Engineer« Go to the
Project view
and select the 8400 HighLine inverter.
2. Select the
Application parameters
tab from the
Workspace
.
3. Go to the
Overview
dialog level and click the following button:
Parameterisation dialog in the »Engineer«
• Via the
From Motor Catalogue
button, the motor catalogue can be opened to select another
motor.
Selecting a motor from the motor catalogue in the »Engineer«
• Via the
From inverter
... button, the motor data set in the inverter can be copied to the
»Engineer« when an online connection has been established.
• When an online connection has been established to the inverter, the
Identification in progress...
button serves to automatically identify different motor data.
• The
Encoder/feedback system...
button serves to get to the settings for the encoder/feedback