Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
895
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00442
C00443
Value is bit-coded: (
= bit set)
Bit 0
SafeTorqueOff
Bit 1
ReadyToSwitchOn
Bit 2
SwitchedOn
Bit 3
Reserved
Bit 4
Trouble
Bit 5
Fault
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Fail CAN_Management
Bit 10
Reserved
Bit 11
Energy saving mode
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00441 | Decoupling AnalogOut
Data type: UNSIGNED_16
Index: 24134
d
= 5E46
h
Parameter | Name:
C00442 | AOutx: Decoupling value
Data type: INTEGER_16
Index: 24133
d
= 5E45
h
From version 04.00.00
Definition of the value the analog output terminals are to have in the decoupled state.
Configuring exception handling of the output terminals
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C00442/1
0.00 %
AOut1_U: Decoupling value
C00442/2
0.00 %
AOut2_U: Decoupling value
C00442/3
0.00 %
AOut1_I: Decoupling value
C00442/4
0.00 %
AOut2_I: Decoupling value
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00443 | DIx: Level
Data type: UNSIGNED_16
Index: 24132
d
= 5E44
h
Bit coded display of the level of the digital inputs
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info