C00919
C00920
C00922
C00937
Parameter | Name:
C00919 | Moment of inertia from load
Data type: UNSIGNED_32
Index: 23656
d
= 5C68
h
From version 12.00.00
In order to take account of mass inertias changing during the process (e.g. reels) when optimising the response to
setpoint changes, the maximum value of the changing moment of inertia must be set here. The process signal
nInertiaAdapt_a
of the
SB can then be used in the process to dynamically control what
percentage of it is to be taken into account for the setpoint feedforward control.
Setting range
(min. value | unit | max. value)
0.00
kg cm^2
6000000.00
Subcodes
Lenze setting
Info
C00919/1
0.00 kg cm^2
Load moment of inertia
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00920 | Rated device currents
Data type: UNSIGNED_16
Index: 23655
d
= 5C67
h
Display range
(min. value | unit | max. value)
0.0
A
6000.0
Subcodes
Info
C00920/1
Rated current 3ph 400V/1ph 230V
C00920/2
Rated current 3ph 440V
C00920/3
Rated current 3ph 480V
C00920/4
Rated current 3ph 500V
C00920/5
Increased rated current 3ph 400V/1ph 230V
C00920/6
Increased rated current 3ph 440V
C00920/7
Increased rated curent 3ph 480V
C00920/8
Increased rated current 3ph 500V
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00922 | ICM_DiagnosticCounter
Data type: UNSIGNED_16
Index: 23653
d
= 5C65
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00937 | Field-oriented motor currents
Data type: INTEGER_16
Index: 23638
d
= 5C56
h
From version 11.00.00
Field weakening for synchronous motors
Display range
(min. value | unit | max. value)
-320.00
A
320.00
Subcodes
Info
C00937/1
Field-producing current
C00937/2
Torque-producing current
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100