C00338
C00339
C00341
Parameter | Name:
C00338 | L_Arithmetik_1: Function
Data type: UNSIGNED_8
Index: 24237
d
= 5EAD
h
The
FB: Selection of internal arithmetics
Selection list
(Lenze setting printed in bold)
0 Out = In1
1 Out = In1 + In2
2 nOut_a = nIn1_a - nIn2_a
3 Out = (In1 * In2) / 100%
4 nOut_a = (nIn1_a * 1%) / |nIn2_a|
5 nOut_a = (nIn1_a * 100%) / (100% -
nIn2_a)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00339 | L_Arithmetik_2: Function
Data type: UNSIGNED_8
Index: 24236
d
= 5EAC
h
The
FB: Selection of internal arithmetics
Selection list
(Lenze setting printed in bold)
0 nOut_a = nIn1_a
1 nOut_a = nIn2_a
2 nOut_a = nIn1_a - nIn2_a
3 nOut_a = (nIn1_a * nIn2_a) / 100%
4 nOut_a = (nIn1_a * 1%) / |nIn2_a|
5 nOut_a = (nIn1_a * 100%) / (100% -
nIn2_a)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00341 | CAN management - error configuration
Data type: UNSIGNED_16
Index: 24234
d
= 5EAA
h
From version 04.00.00
Selection of the events for which the
bFail
error output of the
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF
0x0000
(decimal: 0)
Value is bit-coded: (
= bit set)
Info
Bit 0
BusOff_MsgErr
Bit 1
Warning
Bit 2
NodeStopped
Bit 3
HeartBeatEvent
Bit 4
CAN1_In_Überw.
Bit 5
CAN2_In_Überw.
Bit 6
CAN3_In_Überw.
Bit 7
CAN4_In_Überw.
From version 15.00.00
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved