Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1332
17
Function library
17.1
Function blocks | L_Curve_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.67
L_Curve_1
Alternatively, this FB represents a characteristic curve or cam function y=f(x), whereby the input
signal of the X-axis and the output signal of the Y-axis correspond.
• A limitation of the input value can be set in
(upper limit) and
(lower limit).
• The output value is internally limited to ±199.99 %. If a limitation of the output value is active,
bLimit
is set to TRUE.
Inputs
Outputs
Parameters
Designator
Data type
Information/possible settings
nIn_a
INT
Input value (x)
• ±16384
≡
±100 %
• A limitation of the input value can be set in C00961/1 (upper limit) and C00961/2
(lower limit).
Designator
Data type
Value/meaning
nOut_a
INT
Output value (y)
• ±16384
≡
±100 %
• Internal limitation to ±32767 (±199.99 %)
bLimit
BOOL
"Limitation active" status signal
TRUE The output value is limited to ±199.99 %.
Parameters
Possible settings
Info
From version 11.00.00
-199.99
%
199.99 Output value
• Read only
Function selection
0
nOut_a
= 0 (FB deactivated)
Lenze setting
1
nOut_a
=
nIn_a
2
nOut_a
= f(x)
In preparation!
3
nOut_a
= f(table)
-199.99
%
199.99 Upper limit for input value
• Lenze setting: 199.99 %
-199.99
%
199.99 Lower limit for input value
• Lenze setting: -199.99 %
/B&XUYHB
Q2XWBD
Q,QBD
E/LPLW
& )XQFWLRQ
[
\
[
\
&
&
&[ ;9DOB
&[ <9DOB
&