7
Technology applications
7.6
"GeneralPurpose" functions
492
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.6.2
Arithmetic
This function links two analog signals arithmetically. The arithmetic function can be parameterised.
[7-24] GeneralPurpose function "Arithmetic"
• For a detailed functional description see the
7.6.3
Multiplication/Division
This function multiplies an analog input signal with a parameterisable factor. The factor must be
selected in the form of a quotient (numerator and denominator).
[7-25] GeneralPurpose function "Multiplication/division"
• For a detailed functional description see FB
nGPArithmetikOut_a
nGPArithmetikIn1_a
nGPArithmetikIn2_a
C00830/12
C00830/13
(In1 * 100%)
5
(In1 * In2)
3
(In1 * 1%)
4
In1 - In2
2
In1 + In2
1
In1
0
C00338
100%
|In2|
(100% - In2)
In1
In2
Out =
±32767
(±199.99%)
Parameters
Info
Lenze setting
Value Unit
L_Arithmetik_1: Function
0: nOut_a = nIn1_a
nGPMulDivIn_a
nGPMulDivOut_a
C00699/1
C00699/2
C00830/82
±32767
±
( 199.99%)
Parameters
Info
Lenze setting
Value Unit
L_MulDiv_1: Numerator
0
L_MulDiv_1: Denominator
10000