C00233
C00234
C00235
C00236
C00241
Parameter | Name:
C00233 | L_PCTRL_1: Root function
Data type: UNSIGNED_8
Index: 24342
d
= 5F16
h
The
FB: Use of the root function at the actual value input
Selection list
(Lenze setting printed in bold)
Info
0 Off
Root function inactive
• The actual value
nAct_a
remains unchanged for
further processing
1 On
Root function active
• The root is extracted of the actual value
nAct_a
for
further processing
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00234 | Oscillation damping influence
Data type: UNSIGNED_16
Index: 24341
d
= 5F15
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
250.00
5.00 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00235 | Oscillation damping filter time
Data type: UNSIGNED_8
Index: 24340
d
= 5F14
h
Setting range
(min. value | unit | max. value)
Lenze setting
2
ms
250
32 ms
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00236 | Field weakening oscillation damping
Data type: UNSIGNED_8
Index: 24339
d
= 5F13
h
Oscillation damping for idling machines
Setting range
(min. value | unit | max. value)
Lenze setting
0
40
14
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00241 | L_NSet_1: Hyst. NSet reached
Data type: INTEGER_16
Index: 24334
d
= 5F0E
h
The
FB: Hysteresis window for the zero detection of the speed output setpoint
• The speed threshold for the zero detection is 1 %
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00
0.50 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100