17
Function library
17.1
Function blocks | L_LimitPhi_2
1403
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.100
L_LimitPhi_2
This FB restricts an angle signal to one value range, whose upper and lower limit can be set via
parameters.
Inputs
Outputs
Parameters
Tip!
Always set the lower limit lower than the upper limit, otherwise value "0" is provided at the
dnOut_p
output.
Designator
Data type
Information/possible settings
dnIn_p
INT
Input signal
Designator
Data type
Value/meaning
dnOut_p
INT
Output signal
Parameters
Possible settings
Info
-2147483647
Incr.
2147483647 Lower limit
• Lenze setting: -2147483647 incr.
-2147483647
Incr.
2147483647 Upper limit
• Lenze setting: 2147483647 incr.
/B/LPLW3KLB
GQ,QBS