15
Parameter reference
15.2
Parameter list
1142
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02817
C02830
Parameter | Name:
C02817 | TP: TouchProbe position
Data type: INTEGER_32
Index: 21758
d
= 54FE
h
From version 06.00.00
Display range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Info
C02817/1
Reserved
C02817/2
Reserved
C02817/3
TPDigIn3: TP position
C02817/4
TPDigIn4: TP position
C02817/5
TPDigIn5: TP position
C02817/6
TPDigIn6: TP position
C02817/7
TPDigIn7: TP position
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000
Parameter | Name:
C02830 | DIx: Debounce time
Data type: UNSIGNED_8
Index: 21745
d
= 54F1
h
Debounce times for the digital inputs